| ac/power | R | Sum of AC active power of all enabled inverters | W |
| ac/yieldtotal | R | Sum of energy converted to AC since reset watt hours of all enabled inverters | Kilo watt hours (kWh) |
| ac/yieldday | R | Sum of energy converted to AC per day in watt hours of all enabled inverters | Watt hours (Wh)
| ac/is_valid | R | Indicator whether all enabled inverters where reachable | 0 or 1 |
| dc/power | R | Sum of DC power of all enabled inverters | Watt (W) |
| dc/irradiation | R | Produced power of all enabled inverter stripes with defined irradiation settings divided by sum of all enabled inverters irradiation | % |
| dc/is_valid | R | Indicator whether all enabled inverters where reachable | 0 or 1 |
| [serial]/cmd/limit_persistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will survive the night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. | % |
| [serial]/cmd/limit_persistent_absolute | W | Set the inverter limit as a absolute value. The value will survive the night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. | Watt (W) |
| [serial]/cmd/limit_nonpersistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. The value must be published non-retained, otherwise it will be ignored! | % |
| [serial]/cmd/limit_nonpersistent_absolute | W | Set the inverter limit as a absolute value. The value will reset to the last persistent value at night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. The value must be published non-retained, otherwise it will be ignored! | Watt (W) |